Inter-M PMU-360N User Manual
Page 27

※ Warning : For high impedance systems, connect with matching transformer as the following Figure. Be
certain that the total impedance does not equal less than the rated impedance.
SP 5 is output terminal with ATTENUATOR function, and a recommended speaker is lower than 50W(total
impedance is upper than 200Ω). Please be careful of connecting the speakers.
Please do not use a 8Ω and SP1~SP5 terminal at the same time.
Low Impedance
(100V)
(70V)
PMU-360N
8Ω
28Ω
14Ω
PMU-480N
8Ω
21Ω
11Ω
PMU-600N
8Ω
16Ω
8Ω
MIXING AMPLIFIER
25
PMU-360N/480N/600N