I/O Contact Point Terminal for Remote Control
I/O Contact Point Terminal for Remote Control
1. FAN FAULT CONTACT POINT OUTPUT
It displays the status of fan in each channel.
2. DC FAULT CONTACT POINT OUTPUT
It displays the status of DC power in each channel.
3. REMOTE POWER CONTACT POINT INPUT
It can turn on the amp in ST-By remotely throughout contact point. Amp operated remotely throughout the
contact point will not be switched to ST-BY even if power button of the module is off. It will be restored if
contact point is cleared.
4. AMP FAULT CONTACT POINT OUTPUT
It displays the status of amp in each channel.
5. PRIORITY SELECT CONTACT POINT INPUT
It displays the status of AC power in each channel.
6. AC FAULT CONTACT POINT OUTPUT
When contact point is off, PGM input will be output to the speaker, and contact point is on, PRI input will be
output to speaker. PRI input can be selected only by contact point.
3
2
1
6
5
4
CONTACT ON (SHORT)
CONTACT OFF (OPEN)
REMOTE POWER CONTACT INPUT
ON
OFF
PRIORITY SELECT CONTACT INPUT
ON
OFF
AC FAULT CONTACT OUTPUT
AC FAULT
AC OK
DC FAULT CONTACT OUTPUT
DC FAULT
DC OK
AMP FAULT CONTACT OUTPUT
AMP FAULT
AMP OK
FAN FAULT CONTACT OUTPUT
FAN FAULT
FAN OK