IDEC SG4 Type 4 Finger & Hand User Manual
Page 3

For emitter:
Function
Status
Meaning
LED
DIGIT
TEST
(green ON)
Light curtain being tested. OSSD status on
the receiver must be OFF
Normal operation
Emission
(green ON yellow
ON)
Light curtain in normal operating condition
Function
Type
Check and repair
LED
DIGIT
Internal error
(green ON)
Switch OFF and switch ON the power
supply circuit. If the failure continues
contact DATASENSOR
Optical error
(green ON)
Switch OFF and switch ON the power
supply circuit. If the failure continues
contact DATASENSOR
Error status
No power supply
(LEDs OFF)
Check connections and input voltage
correct value. If the failure continues
contact DATASENSOR
6
Receiver
Emitter
Signals are clearly identified through symbols allowing immediate reading, independent of bars directions.
A short description of the signalling LEDs is necessary to avoid misunderstandings.
Two yellow LEDs (
LAST,
SYNC) on SG4-B receiver, facilitate the alignment procedure.
Correct alignment procedure
The light curtain alignment can be effected only after having completed the mechanical installation and the
electrical connections. The following procedure has to be followed:
NOTE: SG4-B is equipped with a system which informs the user on the alignment obtained.
The alignment function can be activated when powering the device, by keeping the normally open
RESET/RESTART contact closed for at least 0.5 seconds.
Display
LED
NORMAL
OP.
LED
SAFE
(BREAK)
LED
yellow
SYNC
LED
yellow
LAST
Condition
Alignment
Status
ON
Sync NOK
Last NOK
OFF
ON
Sync OK
Last NOK
OFF ON
OFF OFF
Sync OK
Last OK
Middle optics NOK
NO align.
ON OFF
OFF
OFF
Each beam is over the min.
operating threshold and the
number of beam over the
threshold is included between
0 and 25%
MINIMUM
align.
ON OFF
OFF
OFF
Each beam is over the min.
operating threshold and the
number of beam over the
threshold is included between
25 and 50%
ON
OFF
OFF
OFF
Each beam is over the min.
operating threshold and the
number of beam over the
threshold is included between
50 and 75%
ON
OFF
OFF
OFF
Each beam is over the min.
operating threshold and the
number of beam over the
threshold is included between
75 and 100%
MAXIMUM
align.
3
Last optics (LAST)
First optics (SYNC) =
synchronisation optics
NORMAL
OP.
SAFE
(BREAK)
LAST
SYNC
NORMAL
OP.
ON