STRIDER PLUS SERIES

05

4.2 Output Protection

4.2.1 Under voltage protection

4.2.1 Under voltage protection

The +5V/+12V/+3.3V DC output are protected against the under voltage
condition . range value can't be exceed 3.3~3.7V at 5V terminal and
8.5~9.5V at 12V, 2.0~2.4V at 3.3V.

4.2.2 Over Voltage Protection

4.2.2 Over Voltage Protection
The +12V/ DC output are protected against the over voltage condition .
Maximum value can't be over 15.5V at 12V.

4.2.3 Over Power Protection

4.2.3 Over Power Protection
The power supply can be used electronic circuit to limit the output current
against exceeding 60% of surge output power or protected against excessive
power delivery since short circuit of any output or over total power at high line.

4.2.4 Short Circuit Protection

4.2.4 Short Circuit Protection
Short circuit placed on +5V,+12V,+3.3V,-12V will latch off. +5VSB will
auto-recovery.

4.2.5 Over-Current Protection

4.2.5 Over-Current Protection
Current protection should be designed to limit the current to operate within safe
operating conditions. Over current protection schemes where only the voltage
output that experiences the over current event is shut off may be adequate to
maintain safe operation of the power supply and the system; however, damage
to the motherboard or other system components may occur. The recommended
over current protection scheme is for the power supply to latch into the shutdown
state. The setting of over current protection for each output rail is as following.

4.2.6 Over-Temperature Protection

4.2.6 Over-Temperature Protection
This power supply includes an over-temperature protection sensor, which can
trip and shut down the power supply at 110℃

06

Frequency

5-55-10 Hz

Duration

30 minutes

Amplitude

0.35 mm

5.1 No Load Start

When power is applied to SST-ST60F-PS with no load connected or under minimum
load connected, neither damage to power supply nor hazards to users will occur.

5.2 Cold Start

The power supply shall operate properly when first applied at normal input voltage
and or so maximum load after 4 hours storage in 0℃ environment.

5.Start Stability

6.1 Temperature and Humidity

6.2 Altitude

The power supply can operate normally at any altitude between 0 to 10000 feet.

6.3 Vibration and Shock

Sweep and resonance search for each of X,Y,Z, axis at the sweep.
RATE of 1/OCTAVE/Min.

6.Environments

7. Conducted EMI

6.1.1 Operating

6.1.1 Operating
Temperature

0 to 40 ℃

Relative Humidity 20 to 90 %

6.1.2 Storage

6.1.2 Storage
Temperature

-40 to 70 ℃

Relative Humidity 20 to 95 % noncondensing