Sst-st50f-es230-manual-v1-p7-p8 – SilverStone ST50F-ES230 User Manual
Page 5

STRIDER ESSENTIAL SERIES
07
The MTBF of the power should be 50,000 hours min
10. MTBF
11.1 Input Voltage
Applying 220Vac for230Vac model.
11.2 Test Condition
Applying 75% loads for the power supply in 40 (+/-5) oC chamber for 4 hours.
11. Burn-In
* T1 : Turn on time ( 2 sec. Max.)
* T2 : Rise time ( ≦ 20mS Max.)
* T3 : Power good turn on delay time ( 100 < T3 < 500 mS )
* T4 : Switch on time (0.5 sec. Max.)
* T5 : Power good turn off delay time ( 1.0 mS Min.) PS-ON/OFF
* T6 : Power hold-on time ( 8 mS Min.)
* Power on-off cycle :
When the power supply is turned off for a minimum of 2.0 sec. and turn on again,
the power good signal will be asserted.
Time Diagram
Figure 1
AC
AC ON
AC OFF
POWER ON
POWER ON
+5Vs
PS-ON/OFF
+5V O/P
Power Good
T1
T4
T3
T2
T5
4.75V
4.75V
0.25V
T6
08
EPS 12V 8PIN connector
Yellow
Yellow
Yellow
Yellow
Signal
+12V
+12V
+12V
+12V
Pin
5
6
7
8
Pin
1
2
3
4
Signal
COM
COM
COM
COM
Black
Black
Black
Black
M/B 24PIN connector
The power supply with active power factor correction, and meet the EN61000-3-2
standards, The power factor is greater than 0.9 at 230V/50Hz, Max. load.
13.Power Factor
14.1 Physical Dimension
150 mm (W) × 86 mm (H) × 140mm (D)
14.2 Connectors
14. Mechanical Requirements
The product shall meet requirement for EN61000-3-2 & EN61000-3-3 :2003
standard of class D, test at 230Vac 50Hz.
12. Harmonics