07

The MTBF of the power should be 50,000 hours min

10. MTBF

11.1 Input Voltage

Applying 220Vac for230Vac model.

11.2 Test Condition

Applying 75% loads for the power supply in 40 (+/-5) oC chamber for 4 hours.

11. Burn-In

* T1 : Turn on time ( 2 sec. Max.)
* T2 : Rise time ( ≦ 20mS Max.)
* T3 : Power good turn on delay time ( 100 < T3 < 500 mS )
* T4 : Switch on time (0.5 sec. Max.)
* T5 : Power good turn off delay time ( 1.0 mS Min.) PS-ON/OFF
* T6 : Power hold-on time ( 8 mS Min.)
* Power on-off cycle :
When the power supply is turned off for a minimum of 2.0 sec. and turn on again,
the power good signal will be asserted.

Time Diagram

Figure 1

AC

AC ON

AC OFF

POWER ON

POWER ON

+5Vs

PS-ON/OFF

+5V O/P

Power Good

T1

T4

T3

T2

T5

4.75V

4.75V

0.25V

T6

08

EPS 12V 8PIN connector

Yellow

Yellow

Yellow

Yellow

Signal

+12V

+12V

+12V

+12V

Pin

5

6

7

8

Pin

1

2

3

4

Signal

COM

COM

COM

COM

Black

Black

Black

Black

M/B 24PIN connector

The power supply with active power factor correction, and meet the EN61000-3-2
standards, The power factor is greater than 0.9 at 230V/50Hz, Max. load.

13.Power Factor

14.1 Physical Dimension

150 mm (W) × 86 mm (H) × 140mm (D)

14.2 Connectors

14. Mechanical Requirements

The product shall meet requirement for EN61000-3-2 & EN61000-3-3 :2003
standard of class D, test at 230Vac 50Hz.

12. Harmonics