beautypg.com

Manual-(p116)-st45sf-v1-1-2.pdf, Specification, Sfx form factor – SilverStone ST45SF Manual User Manual

Page 2

background image

SPECIFICATION

SFX Form Factor
SST-ST45SF

450W Switching Power Supply
Active PFC Circuit
Full Range Input

01

This is the specification of Model SST-ST45SF; AC-line powered switching power
supply with active PFC (Power Factor Correction) circuit, meet EN61000-3-2 and
with Full Range Input features.

The specification below is intended to describe as detailedly as possible the functions
and performance of the subject power supply. Any comment or additional requirements
to this specification from our customers will be highly appreciated and treated as a new
target for us to approach.

The subject power supply will meet the EMI requirements and obtain main safety
approvals

as following:

2.1. EMI REGULATORY

- FCC Part 15 Subpart J, Class ‘B’ 115 Vac operation.
- CISPR 22 Class ‘B’ 230 Vac operation.

1.GENERAL DESCRIPTION AND SCOPE

2. REFERENCE DOCUMENTS

02

3. INPUT ELECTRICAL SPECIFICATIONS

3.1. AC INPUT

Parameter

Parameter

Min.

Nom.

Max

Unit

Maximum inrush current from power-on (with power on at any point on the AC sine)
and including, but not limited to, three line cycles, shall be limited to a level below the
surge rating of the input line cord, AC switch if present, bridge rectifier, fuse, and EMI
filter components. Repetitive ON/OFF cycling of the AC input voltage should not
damage the power supply or cause the input fuse to blow.

(At Full load)

3.2. INRUSH CURRENT

3.3. INPUT LINE CURRENT & POWER FACTOR (P.F.)

3.4. EFFICIENCY

(1)

Vin (115VAC)

90

115

135

VAC rms

Vin (230VAC)

180

230

265

VAC rms

Vin Frequency

47

--

63

HZ

AC input

Input line current

P.F.@ Full Load

P.F.@ Pin=75W

115V

< 5.5Amps – rms

> 0.95

> 0.8

230V

Loading

Required Minimum Efficiency

Required Minimum Efficiency

< 3Amps – rms

> 0.9

Voltage

115V

230V

Full load

>82%

>84%

>82%

>84%

Typical load

>85%

>87%

Light load

> 0.65

Nominal voltages for test purposes are considered to be within ±1.0V of nominal.

Minimum Efficiency for test purposes are considered to be within ±1.0% of nominal.

SFX Form Factor