beautypg.com

P1-p2, Specification, Sfx form factor – SilverStone ST45SF-G User Manual

Page 2

background image

SFX Form Factor

SPECIFICATION

SFX Form Factor

ST45SF-G

450W Switching Power Supply

Active PFC Circuit

Full Range Input

01

This specification describes the requirements of 450W with full range voltage,
switching power supply with a SFX form-factor.

1.1 AC input requirements

The input voltage, current, and frequency requirements for continuous operation
are stated below.

1.2 Inrush current regulation

The power supply must meet inrush requirements for any rated AC voltage, during
turn on at any phase of AC voltage, during a single cycle AC dropout condition,
during repetitive ON/OFF cycling of AC, and over the specified temperature range
(Top). The peak inrush current shall be less than the ratings of its critical components
(including input fuse, bulk rectifiers, and surge limiting device).

Table 1 AC Input Line Requirements

Power factor correction (PF)>0.90 at full load.

Parameter

Vin

Vin Frequency

Iin

Min

90

47

Max

264

63

Unit

VACrms

Hz

A

Nom.

100

60

7.0

240

50

3.5

1. AC INPUT

02

2. DC OUTPUT

2.1 DC voltage regulation

2.2 LOAD RANGE

2.3 Output Ripple

Parameter

+3.3V

+5V

+12V

-12V

+5VSb

At no load,3.3V output +/-5% regulation limits do not apply.

(1) The maximum combined load on +3.3V and +5V outputs shall not exceed 90W.
(2) Maximum continuous total DC output power should not exceed 450W.

Range

±3%

±3%

±3%

±10%

±5%

Min

+3.20

+4.85

+11.64

-10.8

+4.75

Nom.

+3.3

+5.0

+12.0

-12.0

+5.0

Max

+3.39

+5.15

+12.36

-13.2

+5.25

Unit

Volts

Volts

Volts

Volts

Volts

Parameter

+3.3V

+5V

+12V

-12V

+5VSb

Parameter

+3.3V

+5V

+12V

-12V

+5VSb

Ripple&Noise

50

50

120

120

50

Unit

mVp-p

mVp-p

mVp-p

mVp-p

mVp-p

Min

0

0

0

0

0

Nom.

-

-

-

-

-

Max

19

14

37

0.3

2.5

Peak

Unit

Amps

Amps

Amps

Amps

Amps

2.3.1 Ripple regulation