006

Equipment Configuration Error
Causes:
1. CPU BIOS Update Code Mismatch
2. IDE Primary Channel Master Drive Error
(THe causes will be shown before “Equipment Configuration
Error”)

010

Memory Error at xxxx:xxxx:xxxxh (R:xxxxh, W:xxxxh)

070

Real Time Clock Error

071

CMOS Battery Bad

072

CMOS Checksum Error

110

System disabled.
Incorrect password is specified.

Battery critical LOW
In this situation BIOS will issue 4 short beeps then shut down
system, no message will show.

Thermal critical High
In this situation BIOS will shut down system, not show message.

Error Message List

Error Messages

FRU/Action in Sequence

Failure Fixed Disk

Reconnect hard disk drive connector.
“Load Default Settings” in BIOS Setup Utility.
Hard disk drive
System board

Stuck Key

see “Keyboard or Auxiliary Input Device Check” on page 59.

Keyboard error

see “Keyboard or Auxiliary Input Device Check” on page 59.

Keyboard Controller Failed

see “Keyboard or Auxiliary Input Device Check” on page 59.

Keyboard locked - Unlock key switch

Unlock external keyboard

Monitor type does not match CMOS - Run Setup Run “Load Default Settings” in BIOS Setup Utility.

Shadow RAM Failed at offset: nnnn

BIOS ROM
System board

System RAM Failed at offset: nnnn

DIMM
System board

Extended RAM Failed at offset: nnnn

DIMM
System board

System battery is dead - Replace and run Setup

Replace RTC battery and Run BIOS Setup Utility to reconfigure
system time, then reboot system.

System CMOS checksum bad - Default
configuration used

RTC battery
Run BIOS Setup Utility to reconfigure system time, then reboot
system.

System timer error

RTC battery
Run BIOS Setup Utility to reconfigure system time, then reboot
system.
System board