MAINTENANCE & REPAIR
We recommend inspection of the impeller every six months if the fan is operated continuously.
Internal insulation or dust may be wiped clean with a dry cloth. Strong detergents or cleaning liquid
must not be used for cleaning the fan. If in the condition of heavy dust, it’s suggested to clean up at
times to prevent duct affecting it operation.
Easy to disassemble. The motor and impeller could be cleaned up by removing plastic/steel clamp,
suspender, connecting box and then unscrewing the four pieces bolts on the housing.
MODEL
RI-150C
RI-200C
RI-250C
RI-500C
RI-700C
RI-900C
92
102
105
235
220
210
0.80
0.86
0.88
2.03
1.88
1.80
141
194
264
558
676
882
2450
2420
2620
2530
2660
2730
2.7
3.0
3.5
4.1
5.5
4.9
F
F
F
F
F
F
Power
(W)
Current
(A)
Airflow
(CFM)
Rotation
(rpm)
Sones
Insulation
Class
RATINGS
NOTE: Rated voltage and frequency are stated as per rating label.
NOTICE
This unit is not intended for use by person (Including children) with reduced physical, sensory or
mental capabilities or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the unit by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the unit.
www.reversomatic.com