9060 power supply kit - introduction – Ransburg 9060 Power Supply Kit 80104 Ext. Cascade (AEMD600) User Manual
Page 17
9060 Power Supply Kit - Introduction
CP-13-01.1
14
The following instructions apply to equip-
ment covered by certificate number Sira
11ATEX5240X:
1. The equipment may be used with flam-
mable gases and vapors with apparatus
groups II and with temperature class T6.
2. The equipment is only certified for use in
ambient temperatures in the range
+12.8
o
C to +40
o
C and should not be
used outside this range.
3. Installation shall be carried out by suita-
bly trained personnel in accordance with
the applicable code of practice e.g. EN
60079-14:1997.
4. Inspection and maintenance of this
equipment shall be carried out by suita-
bly trained personnel in accordance with
the applicable code of practice e.g. EN
60079-17.
5. Repair of this equipment shall be carried
out by suitable trained personnel in ac-
cordance with the applicable code of
practice e.g. EN 60079-19.
6. Putting into service, use, assembling,
and adjustment of the equipment shall
be fitted by suitably trained personnel in
accordance with the manufacturer's doc-
umentation.
Refer to the "Table of Contents" of this ser-
vice manual:
a. Installation
b. Operation
c. Maintenance
d. Parts Identification
7. Components to be incorporated into or
used as replacement parts of the equip-
ment shall be fitted by suitably trained
personnel in accordance with the manu-
facturer's documentation.
8. The certification of this equipment relies
upon the following materials used in its
construction:
If the equipment is likely to come into
contact with aggressive substances, then
it is the responsibility of the user to take
suitable precautions that prevent it from
being adversely affected, thus ensuring
that the type of protection provided by the
equipment is not compromised.
Aggressive substances: e.g. acidic liquids or
gases that may attack metals, or solvents
that may affect polymeric materials.
Suitable precautions: e.g. regular checks as
part of routine inspections or establishing
from the material's data sheets that it is re-
sistant to specific chemicals.
Refer to "Specifications" in the "Introduction"
section:
a. All fluid passages contain stainless
steel or nylon fittings.
b. High voltage cascade is encapsulated
with a solvent resistant epoxy.
9. A recapitulation of the certification mark-
ing is detailed in the "Atex" section, on
the next page, drawing numbers: 80108
and 80075.
10. The characteristics of the equipment shall
be detailed e.g. electrical, pressure, and
voltage parameters.
The manufacturer should note that, on being
put into service, the equipment must be ac-
companied by a translation of the instructions
in the language or languages of the country
in which the equipment is to be used and by
the instructions in the original language.
EUROPEAN ATEX DIRECTIVE 94/9/EC, ANNEX II, 1.0.6