8
No. 2 Process Handgun Spray Techniques
TUBULAR WORK
The gun should normally be positioned about 4 to 6
inches from the part and held almost perpendicular
to the target surface. Spraying too close to the
part may cause runs and sags. Spraying too far
away from the part may cause overspray or allow
paint to wrap-back towards the gun.
Moving the gun in a straight line may not always
produce the most complete coverage or uniformity.
(See example "A".)
A slight waving or rotation of the gun can help
to spread the paint around the part better and
improve coverage. (See examples "B" and "C".)
>
Small tubes (up to about 2-1/2 inches)
often may be coated by wrap-around from
one side. Larger parts are harder to wrap
completely from one side because paint
must miss target to wrap-around
Example: Not complete wrap-around, but
still good attraction and efficiency.
NOTE
A
B
C
- RCS 2 Ratio Control System (82 pages)
- DynaFlow Programmers Manual (59 pages)
- DynaFlow User Manual (100 pages)
- Vector Solo 79901 Waterborne RS90-WB (66 pages)
- Vector Solo 79900 Solventborne RS90-AS (64 pages)
- Vector_Solo Technical Manual (16 pages)
- Solo Installation & Set-Up Kit (8 pages)
- Vector Solo AA90 79698 (58 pages)
- Vector Solo 65KV 79965 Solventborne RS70-AS (60 pages)
- Vector R Series Classic 79503 R90 Solventborne (74 pages)
- Vector R Series Cascade 79500 R90 Solventborne (78 pages)
- Vector AA90 79580 Cascade (62 pages)
- No. 2 Process Handgun Electric Motor (61 pages)
- No. 2 Air Motor Atex Approved Unit 80086-XX (63 pages)
- 9060 HV P.S. Air Motor 80102-31X (36 pages)
- 9060 HV P.S. Electric Motor 80102-21X (42 pages)
- REA Automatic Applicators 77359, 76110, 77140 (66 pages)
- Evolver SE Robotic Atomizer A12455-XXXXXXXX (79 pages)
- 9060 LV Auto Cascade 80120-XXX (56 pages)
- 9060 HV Auto Classic 80100-XXX (56 pages)
- Turbodisk Applicator Assembly A11376 (78 pages)
- Turbodisk Fairing Assembly 70158 (17 pages)
- MMA-303 Direct_Ind Test Stand (26 pages)
- MMA-303 Direct_Ind Charge Atomizer A12870 (132 pages)
- MMA-570 Direct_Ind Charge Atomizer A13366 (109 pages)
- Aerobell (Std.) Rotary Atomizer A12381 (89 pages)
- 9040 Aerobell Control Module 78387-00 (33 pages)
- Aerobell 33 AER5000, AER5001 (57 pages)
- Aerobell 168 A12787 (116 pages)
- Aerobell 168 Atex Approved 13350 (106 pages)
- RPA-2 Powder Applicator A12950-XXX (47 pages)
- RMA Indirect A11600 (103 pages)
- RMA Indirect A12869 (121 pages)
- Test Stand RMA-303, EVOLVER, EVOLVER NE (28 pages)
- RMA Dual Purge Direct A12300 (116 pages)
- RMA Dual Purge Direct A12868 (120 pages)
- RMA-560 Single_Dual Purge Direct A13364 (104 pages)
- RMA Direct A12867 (118 pages)
- Evolver Solvent Robot Applicator 79190-XXXXXXXX (82 pages)
- Evolver 303 Solvent Applicator A11976-XXX (85 pages)
- Evolver 303 Dual Purge Solvent Robotic Applicator A12374-XXX (86 pages)
- Evolver MicroPak Controller A10406 (37 pages)
- Voltage Master 2 78789_LEPS5001 (51 pages)
- PulseTrack2 A11515-XXXXX (58 pages)