Connection instructions, Leak test – King Kooker Fire Pit User Manual
Page 13

connectIon InstructIons
1. Check that your manual valve is set to not allow gas flow. The manual valve should be 90 degrees
to the line of gas flow. See below Figure 1. This is the OFF position.
2. Attach the regulator to the cylinder valve by turning the Type 1 fitting clockwise. Refer to the
assembly diagram for the appliance below.
3. Perform the Leak Test:
4. Before lighting the appliance, check that the venturi tube is free of obstruction and that the orifice
located on the valve is properly threaded into the venturi tube. Both situations must be corrected
if necessary before lighting to prevent flashback.
13
leAK test
Before lighting the appliance, a thorough leak test must be satisfactorily completed using
a non-ammonia soapy water solution (50% non-ammonia soap and 50% water). This is to be
applied with a small brush to all gas joints after the cylinder valve is opened (no more than
1/2 turn). If bubbles are seen, indicating a leak, turn off the cylinder and tighten the leaking
connection until a further leak test shows no leaks.
If tightening the connection does not stop the leak, call Metal Fusion, Inc. (800) 783-3885,
for assistance.
neVer use Hose/reGulAtor Assembly IF leAKInG.
mAnuAl VAlVe
(oFF PosItIon)
tyPe 1
connectIon
non-AdJustAble
Pressure
reGulAtor
20 lb.
lP GAs
cylInder