GENERAL PUMP

A member of the Interpump Group

VK SERIES

Page 11

The pump’s shaft (PTO) must not be rigidly connected to the motor unit.

The following transmission types are suggested:

• Flexible joint

• Cardan Joint (please respect the maximum working angles indicated by the manufacturer)

• V-belts, only allowed on versions without a reduction gear

9. PUMP INSTALLATION

9.1 Installation

The pump must be fixed horizontally using the M16x1.5 threaded support feet. Tighten the screws with a torque of

155 Ft.Lb. (210 Nm). The base must be perfectly flat and rigid enough as not to allow bending or misalignment on the

pump coupling axis/transmission due to torque transmitted during operation.

The unit cannot be fixed rigidly to the floor must must be protected with vibration dampeners. For special applications

contact the Customer Service Department.

A lifting bracket is mounted on the pump for easy installation, as per the figure below.

Replace the oil plug (red) positioned on the rear casing cover. Check the correct quantity with

the oil dipstick.

The oil dipstick must always be reachable, even when the unit is assembled.