Tx series “63” servicing instructions, General pump – General Pump TX-63 Series User Manual
Page 3

GENERAL PUMP
A member of the Interpump Group
G
GEEN
NEER
RA
ALL PPU
UM
MPP 1174 Northland Drive • Mendota Heights, MN 55120
Phone: (651)686-2199 • Fax: (800)535-1745 • e-mail: [email protected] • www.generalpump.com
Ref 300685 Rev. B
02-12
TX Series “63”
Servicing Instructions
Replacing packings:
1) Remove manifold from crankcase.
2) Insert proper extractor collet through main seal retainer.
Tighten collet and extract retainers, packings and
head rings.
3) Apply grease to the packing assembly before installing in
cylinders.
4) Place proper insertion tool in cylinder and install packing
assembly, retainer and low pressure seal retainer using
the proper insertion tool.
5) Repeat this sequence for each cylinder.
6) Align outside pistons in forward position.
7) Coat each plunger with grease.
8) Install manifold and torque retainers to specifications.
Recommended Tools/Supplies:
1) KINSTX63 Packing Insertion Kit, 63 Series
2) 100783 Complete Extraction Kit
Includes the following tools:
2530016 handle
2530020 15mm sleeve
2530017 bolt
2530021 18mm sleeve
2530018 pin
3) 190446 Oil Drain Kit
4) 100295 General Pump Series 100 Oil (1-16 oz. bottle)
100214 General Pump Series 100 Oil (6-16oz. bottles)
100216 General Pump Series 100 Oil (24-16 oz. bottles)