Htck3623s – General Pump HTCK3623S User Manual
Page 13

GENERAL PUMP
A member of the Interpump Group
HTCK3623S
To reassemble the various components, follow the reverse operations listed above as described in point
2.2.1. To facilitate insertion of the valve guide in its housing, you can use a brush resting on the horizontal
guide planes and use a hammer acting on the whole circumference (figs. 19a).
Page 13
Insert the suction and outlet valve units, checking that they are down to end stroke in the head
housing. Then apply the valve covers and calibrate the respective M12x25 screws using a
torque wrench at the required tightening torque.
2.2.3 DISMANTLING THE HEAD - SEALS
Replacement of the seals is necessary from the moment you begin to detect water leaks from the drainage
holes provided on the back of the pump casing, and at the intervals indicated in the “Preventive Maintenance”
section on the specification sheet.
A) Unscrew the M10x110 head fixing screws as indicated in fig. 20.
Ref 300935 Rev.A
09-13
B) Separate the head from the pump casing
C) Extract the high pressure seals from the head and the low pressure ones from the support, using simple
tools as indicated in (fig. 21) being careful not to damage the respective housing.