beautypg.com

Specifications – Fairbanks 9106 FB Omnicell User Manual

Page 8

background image

Section 1: General Information

10/07

8

51176 Rev. 2

SPECIFICATIONS

Capacities

1,000, 1,500, 2,500, 5,000, and 10,000 lbs.

Mount Construction

304 Stainless Steel

Full Scale Output (FSO)

3.0mV/v ± 0.25%

Combined Error (FSO)

≤ 0.03%

Non-Linearity (FSO)

≤ 0.03%

Hysteresis (FSO)

≤ 0.02%

Creep Error (30 min.)

≤ 0.03%

Compensated Temperature

14° to 104° F (-10° C to 40° C)

Operating Temperature

-40° to 176° F (-40° to 80° C)

Excitation Voltage

5-15 VDC

Mechanical Overload

• Safe = 150% • Ultimate = 300%

Sideload

Safe = 100%

Bridge Resistance

350 ohms nominal

Load Cell Construction

Stainless Steel 17-4 PH

Sealing

Welded Seal

Cable

20 ft. Polyurethane

Protection

IP 67

Approvals

Factory Mutual Approved