50768
7
01/08 Rev. 2
JACKING SCREW
JACKING SCREW
GROUNDING LUG
GROUNDING LUG
TOP PLATE
TOP PLATE
BASE PLATE
BASE PLATE
3/4"-10 UNC (2x) (22.5K)
3/4"-10 UNC (2x) (22.5K)
5/8"-11 UNC (2x) (11.25K)
5/8"-11 UNC (2x) (11.25K)
7/16"-14 UNC (2x) (4.5K and under)
7/16"-14 UNC (2x) (4.5K and under)
(Bolts not provided)
3/8"-16 UNC (4x) (4.5K & under)
3/8"-16 UNC (4x) (4.5K & under)
UPLIFT PROTECTION
UPLIFT PROTECTION
7/16"-14 UNC (4x) (11.25K )
7/16"-14 UNC (4x) (11.25K )
5/8"-11 UNC (4x) (22.5K )
5/8"-11 UNC (4x) (22.5K )
(Bolts not provided)
C
D
E
F
H
I
J
K
L
M
N
G
A
B
(Optional)
50768-1
DIMENSIONS (in inches) Corresponds to drawing above.
Capacity (lbs)
A B C D E F G H I J K L M N
1.125k, 2.25k, 4.5k
3.54 0.59 1.18 6.30 5.12 1.57 0.98 6.50 3.15 0.47(4x) 0.47 2.76 1.97 3.94
11.25k
5.12 0.79 1.97 7.87 6.69 2.17 1.38 8.47 4.13 0.56(4x) 0.63 3.94 2.76 5.12
22.50k
6.30 0.98 1.97 10.24 8.67 2.17 1.38 10.24 5.31 0.73(4x) 0.79 5.12 2.76 5.91