Fairbanks Ultegra Health Scale User Manual
Page 4
Section 1:
Introduction & Description
A.
Introduction
The Ultegra
™
Health Scale is powered by a 12-volt AC adapter. It has a capacity of 600
pounds, and is constructed of ABS composite material.
B.
Description
The scale is designed for personal weighing applications. It includes a large, easy-to-
read remotely mounted LCD display and a 9-pin RS232 output cable.
To prevent personal injury, please read this booklet before
using your scale!
1.
Power supply must be used with a correctly grounded outlet.
2.
Do not place your scale on a soft, wet or slippery floor. You should place your scale
on a solid and level floor.
3.
Avoid extremes in temperature, humidity, shock, moisture and dust.
4.
Do not step on your scale with wet feet. Make sure that feet are dry to prevent
slipping and/or serious injury.
5.
Do not service this unit yourself. Refer servicing to a qualified technician.
C.
Specifications
1.
Technical Specifications
a.
Capacities:
600 lb/272 kg
b.
Resolution: Programmable
0.2 lb / 0.1 kg
Commercial Setting
0.1 lb / 0.05 kg
Non-Commercial Setting
c.
Commercial Divisions:
3000 divisions
c.
Rounding:
1 division
d.
Weight update rate:
0.4 seconds
e.
Motion Detection:
1 division, satisfies H-44 requirements
f.
Power Failure Protection:
Zero reference, programming, and calibrations are retained if the instrument
loses power.
08/08
4
50735 Rev. 6
!
WARNING