INDICATOR ERROR CODES
There are several error conditions and operational steps indicated by the scale.
•
Not all are applicable in every sequence.
•
Some errors are indicated using audible beeps and some are shown on the scale
display.
LCD Display Indicators
Displayed Text or Annunciator
Description
- - - -
No Bluetooth
®
connection is established.
Motion/Stable Annunciator
Weight is stable on the scale.
Lb Annunciator
Displayed weight is in pounds.
Connection Annunciator
Connection is established between J-Box/Indicator/Software.
-dL-
Too many digits to display.
- U L -
Weight is Under Load capacity.
- O L -
Weight is Over Load capacity.
ErrC
BlueLine
Indicator
or Software calibration sequence
failed.
Good
Calibration sequence is successful.
COnn
Indicator connected to BlueLine
Software.
Lbat
Battery charge below the operating range.
Conf
Scale in Configuration Mode. Program changes are possible.
Battery Annunciator
Battery charge getting low warning.
Counter-clockwise Dashes
The Zero button is held down, turning the display off.
Audible Beep Errors/Signals
Alerts
Displayed Message
Description
Pulsing
(5-sec. beeps)
Ring
Indicator searching for BlueLine
Software
connection.
Pulsing
(10-sec. beeps)
CaLL
Indicator attempting to pair with J-box.