Safety procedures – Direct Lift Pro9F User Manual
Page 15

Pro9F 9000 lbs. Floor Plate Lift
IN50019 Rev. C 03/30/2009
15
Employees authorized to perform lockout shall ensure that the appropriate energy isolating device (i.e.,
circuit breaker, fuse, disconnect, etc.) is identified for the lift being locked out. Other such devices for
other equipment may be located in close proximity of the appropriate energy isolating device. If the
identity of the device is in question, see the shop supervisor for resolution. Assure that proper
authorization is received prior to performing the lockout procedure.
Sequence of Lockout Procedure
1) Notify all affected employees that a lockout is being performed and the reason for it.
2) Unload the subject lift. Shut it down and assure the disconnect switch is “OFF” if one is provided
on the lift.
3) The authorized lockout person operates the main energy isolation device removing power to the
subject lift.
If this is a lockable device, the authorized lockout person places the assigned padlock on
the device to prevent its unintentional reactivation. An appropriate tag is applied stating
the person’s name, at least 3” x 6” in size, an easily noticeably color, and states not to
operate device or remove tag.
If this device is a non-lockable circuit breaker or fuse, replace with a “dummy” device and
tag it appropriately as mentioned above.
4) Attempt to operate lift to assure the lockout is working. Be sure to return any switches to the
“OFF” position.
5) The equipment is now locked out and ready for the required maintenance or service.
Restoring Equipment to Service
1) Assure the work on the lift is complete and the area is clear of tools, vehicles, and personnel.
2) At this point, the authorized person can remove the lock (or dummy circuit breaker or fuse) &
tag and activate the energy isolating device so that the lift may again be placed into operation.
Rules for Using Lockout Procedure
Use the Lockout Procedure whenever the lift is being repaired or serviced, waiting for repair when
current operation could cause possible injury to personnel, or for any other situation when unintentional
operation could injure personnel. No attempt shall be made to operate the lift when the energy isolating
device is locked out.
Operating Conditions
Lift is not intended for outdoor use and has an operating ambient temperature range
of 41º-104ºF (5º-40ºC).
SAFETY PROCEDURES
• Never allow unauthorized persons to operate lift. Thoroughly train new employees in the
use and care of lift.
• Caution - the power unit operates at high pressure.
• Remove passengers before raising vehicle.
• Prohibit unauthorized persons from being in shop area while lift is in use.
• Total lift capacity is 9,000 lbs. @ 2,250 lbs per lifting pad. Do not exceed maximum
weight capacity of lift.
• Prior to lifting vehicle, walk around the lift and check for any objects that might interfere
with the operation of lift and safety latches; tools, air hoses, shop equipment.