This well engineered, gas water heater has all the fea-
tures a water heater should have:
It operates on the principle of heating water instantaneously
“on demand”. When a hot water faucet is opened, cold
water flows through the coils of the heat exchanger in the
Aquastar. This same flow opens the gas valve, and the
burners are ignited by the pilot flame. The heat exchanger
coils absorb the heat generated by the burners and trans-
fer heat to the water. When the hot water faucet is shut
off, the gas valve automatically closes and the burners
turn off. Your hot water faucet is an ignition key to turn on
the water heater, giving you control over your hot water
energy use. Each time you turn off your hot water faucet,
you also shut off the water heater.

FEATURES

- High Quality Materials for Long Working Life.

- Copper heating coils for endless supply of hot water.

- Safety thermocouple at pilot burner.

- Automatic overheating protection shut-off sensor.

- Stainless steel burners with stabilized blue flame.

- Built-in corrosion resistant draft inducer.

- Compact space saver: mounts on a wall with two hooks.

- Easily removable one-piece cover.

- Easy one person installation.

- Adjustable water flow restrictor to ensure that water flow

demand will not exceed the heating capacity of the
heater.

- Easy pilot flame lighting with push button piezo ignition.

AquaStar 38B LP and 38B NG Specifications

Gas Input max.: 40,000 Btu/hr

min.: 20,000 Btu/hr

Water Connection 1/2” Thread fitting

H x W x D 25 3/8” x 10 5/8” x 9 1/8"

Vent 4”

Gas Connection 1/2” NPT thread

Min. Water Pressure 13 Psi at 1.3 GPM

Max. Water Pressure 150 Psi

Shipping Weight 20 LB

Net Weight 18 LB

0.5 GPM at 90° rise

1.3 GPM at 45° rise

Min. Water Flow 1/2 gal/min

LP GAS Pressure inlet.

min.

11” W.C.

max. 14” W.C.*

LP GAS Manifold pressure 9.0” W.C.**

Natural Gas Pressure inlet

min.: 7” W.C.
max.: 14” W.C.*

Natural Gas Manifold Pressure 5.2 W.C.**

* Inlet gas pressure must not exceed this value

** For purposes of input adjustment