beautypg.com

Installation checklist, Gas line size, Minimum vent size* and height – AquaStar 38B NG User Manual

Page 16

background image

GAS LINE SIZE

Natural Gas

Nominal Iron Pipe Size*

3/8"

1/2"

MAXIMUM LENGTH

20'

80'

Liquid Propane

Semi-rigid Tubing

3/8"

1/2"

MAXIMUM LENGTH

10'

60'

* Flex tubing greatly reduces capacity and, therefore, is not recommended.

Minimum Vent Size* and Height

Minimum Diameter

Minimum Height**

4 inches

6 feet**

* NOTE: Vent size must not be restricted. Installation must comply with national fuel gas code venting requirements

for a 40,000 Btu Category I appliance and any applicable local codes.

Water Pressure

For installation on well systems, insure that your water pressure is between 30 - 50 psi.

** NOTE: 6 feet, provided there are no elbows. Termination of vent must be 2 feet above any obstruction within a

10 foot radius. Consult your gas utility or National Fuel Gas Code if vent will have elbows or share venting with

another appliance. The vent connector should have as much vertical rise as possible (minimum 12") before any

horizontal run.

INSTALLATION CHECKLIST

Replacement Parts available from North American Distributor

CONTROLLED ENERGY CORP.

340 Mad River Park

Vermont 05673 (U.S.A.)

Phone 800-642-3111

Fax (802) 496-6924

WWW.CECHOT.COM