Fine Tuning the Low Level Indicator
1. Locate the calibration screw on
the underside of the MilkChiller™
just behind the drip tray.
2. Fill a container 1/4 full or more with liquid.
This is the approximate amount of dairy product
remaining in the container when the LOW indicator
flashes on the display.
Place container in the MilkChiller™ and close the lid.
3. Place the MilkChiller™ on a flat
surface that will provide access to the
calibration screw. We suggest using an
inside corner of a counter, or pushing two
tables together leaving 2 inches between
them for access to the screw.
4. Using a flathead screwdriver, SLOWLY
adjust screw on the bottom in a clockwise
manner just until the LOW indicator is
flashing.
5. Further adjust the screw ½ turn to
complete the calibration.
The Low Level Indicator has been calibrated
to trigger at approximately 18 ounces, 1/4 of
a carton. This is the minimum amount of
liquid remaining in the carton when the LOW
indicator flashes. The Low Level Indication
can be adjusted to trigger for more liquid
remaining in the carton if desired.
If, after time, the LOW indicator does not
flash at the desired liquid level, readjust the
calibration screw as outlined above.