FEC AFC1200 User Manual
Page 14

)(& ,QF
2. Re-enter the data on the MACHINE CONFIGURATION / SET SEQUENCE / SET
PARAMETER screens (or reload the Preset files from the PRESET FILE UTILITY
screen).
3. ensure that the ISA Main Unit is not located near any strong electrical or magnetic fields.
4. Confirm that the ISA Main Unit input power remains constantly within specifications:
200~230 VAC +/- 10%, 50/60 Hz, single phase.
5. Verify that the ISA Main Unit power cable is free from damage and is properly connected.
6. If the problem persists, replace the entire ISA Main Unit. (Refer to Section 8.3.1)
9.3.8 SYSTEM CONFIG SET ABNORMAL
The SYstem Configuration is set-up incorrectly.
1. Verify that the MACHINE CONFIGURATION / SET SEQUENCE / SET PARAMETER
screens match the physical machine configuration.
2. Re-enter the data on the MACHINE CONFIGURATION / SET SEQUENCE / SET
PARAMETER screens (or reload the Preset files from the PRESET FILE UTILITY
screen).
3. ensure that the ISA Main Unit is not located near any strong electrical or magnetic fields.
4. Confirm that the ISA Main Unit input power remains constantly within specifications:
200~230 VAC +/- 10%, 50/60 Hz, single phase.
5. Verify that the ISA Main Unit power cable is free from damage and is properly connected.
6. If the problem persists, replace the entire ISA Main Unit. (Refer to Section 8.3.1)
9.3.9 CONSOLE DUAL PORT RAM ABNORMAL
Multi2 PCB DUAL PORT error between the Processor PCB and Multi2 PCB.
1. ensure that the ISA Main Unit is not located near any strong electrical or magnetic fields.
2. Confirm that the ISA Main Unit input power remains constantly within specifications:
200~230 VAC +/- 10%, 50/60 Hz, single phase.
3. Verify that the ISA Main Unit power cable is free from damage and is properly connected.
4. If the problem persists, replace the entire ISA Main Unit. (Refer to Section 8.3.1)
Chapter 9: Troubleshooting