P Controller Units must be located a minimum of 600 mm from sources of high
transient voltage such as transformers, AC inverters, AC contactors and motor
starters. If this cannot be avoided, then the units must be properly shielded.
w Static Electricity
AFC1200 System construction incorporates many electronic Surface Mounted
Devices (SMD). It is advisable to strictly adhere to practices for safe electrostatic
discharge in order to prevent damage to the system.
w Cleaning
Do not use any organic solvents, such as thinner, to clean a Controller Unit or a tool.
The solvent could melt the surface paint or penetrate inside and cause damage. A
cloth dampened with alcohol or warm water should be used to lightly wipe the
components.
w Handling and Shipping
It is critical that AFC1200 System components are properly handled and shipped in
order to maintain the System's integrity. Adhere to the following requirements for
shipping and handling:
P All AFC1200 components must be removed from their enclosure(s) prior to
shipping.
P AFC1200 System components must be individually packaged in an approved
anti-static container or wrap to prevent damage from electrostatic discharge.
P Tool assemblies must be removed from the powerhead during shipment to prevent
damage to the transducer assembly.
P Enclosures must be protected with shrink wrap.
P Enclosures and System components should be shipped on an air-ride trailer
whenever possible.
P Adhere to Section 2.1: Main Specifications for environmental requirements.