AFC1500 Multi-2 Unit Hardware Manual (Rev. 2)
PAGE 6 - 2
Chapter 6: Troubleshooting
6.1 Abnormals
The Multi-2 Unit is capable of giving unit fault status to the AFC 1500 User Console in the form of a
code number. This number can be read and displayed by the User Console software. (See the User
Console Software Manual for more information on where to access this function)
Abnormal
Number
Description
1
An Axis unit was not in Ready status when the Multi-2 Unit
attempted to start - confirm all axis status
2
The connected spindles do not match with spindles called
from fastening sequence - confirm fastening sequence
3
Fastening sequence does not have spindle numbers
assigned - confirm fastening sequence
4
Fastening sequence selected does not exist - confirm
fastening sequence.
5
No End command in the fastening sequence
6
Fastening sequence abnormal
7
An Axis unit was not in Ready status when the Multi-2 Unit
attempted to send 1st step command - confirm all axis
status
8
An Axis unit was not in Ready status when the Multi-2 Unit
attempted to send 2nd step command - confirm all axis
status
9
Input / Output port number error - input port number over 4