Wiring Diagram

Wiring Diagram

Wiring Diagram

Wiring Diagram

Wiring Diagram

Circular Connector

3' Analog LED Lighting Control Line, connects to Panel Light Rheostat.

12/24 volts dims the analog LEDs.

3' (

Optional) External Warning Control Line. Can be connected to a

relay to control an external light, buzzer, etc. Grounds when Red

Warning Light is on. Current must be limited to 1/10 amp maximum.

3' Backlight Control Line, connects to 24 Volt Bus via 1 amp fuse (may

use the power fuse). Connect to ground for 12 Volt System.

3' Backlight Control Line, connects to 12 Volt Bus via 1 amp fuse (may

use the power fuse). 12 volts turns on the digital display backlight.

3' Ground Lead, connects to Ground.

3' Power Lead, connects to 12 or 24 Volt Bus via 1 amp fuse or circuit

breaker.

White/Yel

Black

Red

White/Brwn

White/Red

White/Orng

Wire Harness

Do not use screws

Do not use screws

Do not use screws

Do not use screws

Do not use screws

longer than 1/2" (4 ea.).

longer than 1/2" (4 ea.).

longer than 1/2" (4 ea.).

longer than 1/2" (4 ea.).

longer than 1/2" (4 ea.).

23

23

23

23

23

18

Red Wire

6' Grouped wires marked "Left", connects to Left Tank Capacitive Sensor.

Black Wire

White Wire

Red Wire

6' Grouped wires marked "Right", connects to Right Tank Capacitive Sensor.

Black Wire

White Wire