Installation, Adjusting heating element controls, Table 2 table 3 – World Dryer SLIMdri L48 User Manual
Page 4
4
Installation
1. Disconnect the power source.
2. Using Table 2 to determine the recommended mounting height, select a mounting location for the hand dryer where
no reflective surfaces or objects (such as a hand basin) are directly under the infra-red sensor eye. The infra-red
sensor eye is visible from the bottom of the dryer. The minimum mounting distance from bottom of the dryer to a
reflective surface is 18 in (46 cm). When two or more dryers are installed, they should be spaced apart 24 in (61
cm)
3. Use the security hex key supplied to turn the cover mounting screws
clockwise to remove the cover from the dryer.
4. Using the mounting template provided, mark locations for the 4 mounting bolt holes on the wall.
5. Fasten the base to the wall, using the type of bolts recommended in Table 3
6. Each dryer must have its own dedicated circuit.
7. Connect the dryer to the nearest suitable distribution panel.
8. Replace cover, turn screws
counter-clockwise making certain not to over-tighten.
IMPORTANT:
Consult local and general regulations before performing dryer installation. Ensure the electrical
network is not overloaded. Always connect to a dedicated branch circuit with circuit breaker or fuse protection and an
electrical rating greater than the model hand dryer’s rated amperage shown in Table 1 - Electrical Specifications.
Recommended Mounting Heights from Floor to Dryer Bottom Edge
in. (cm.)
Men’s washrooms
46 (117)
Women’s washrooms
44 (112)
Children’s washrooms, ages 4-7
32 (81)
Children’s washrooms, ages 7-10
36 (91)
Children’s washrooms, ages 10-13
40 (102)
Children’s washrooms, ages 13-17
44 (112)
Handicap Mounting Height
37 (94)
Table 2
Table 3
Type of Wall
Type of Bolt
Minimum Bolt Length
Hollow Tile, Lath, Wall Board or Metal
1/4” (M6) screw Type or Wing Type
toggle Bolts
Dependent on wall
thickness
Cement, Brick, or Tile Covered Cement or Brick
1/4” (M6) Stud Type Expansion Bolts
3” (76mm)
Stud Wall with wood Backing
No 16 (M8) Wood Screws
23/4” (70mm)
The dryer can be operated with the heating element “ON” or “OFF”.
Note: The factory setting for the heating element is “ON”.
Adjusting Heating Element Controls