Unpacking description, Electrical specification s, General safety information danger – World Dryer SLIMdri L48 User Manual
Page 2: Danger, Warning, Caution
2
Unpacking
Description
World warm air hand dryer is a surface-mounted ADA (American Disabilities Act) compliant dryer powered by a universal
brush motor, and delivers up to 950 watts of drying power. The dryer incorporates an integrated heating element with
options for operation with, or without, heated air. An infrared sensor is used to automatically activate the dryer. These
models are intended for use in commercial, industrial, office and public facility environments.
Electrical Specification
s
Table 1
General Safety Information
DANGER
Failure to disconnect the power source before installation or servicing can result in serious
injury or death from electric shock.
• Always disconnect the power source before servicing or installing the hand dryer.
DANGER
Failure to properly ground this unit could result in severe electrical shock and/or death.
• This hand dryer must be properly grounded earthed or safe operation. An identified ground connection point is
supplied on the hand dryer’s wall base.
• We recommend GFCI protection in wet or damp locations or as required by local code.
WARNING
Risk of fire, personal injury or property damage are possible if local codes, or safety
recommendations are not followed.
• Installation and servicing should only be performed by qualified electrical technicians.
• Use only the electrical power (voltage and frequency) specified for the model hand dryer being installed. See
Table 1 - Electrical Specifications.
• Connect the hand dryer to the nearest suitable distribution panel. The fixed wiring must include a disconnection
means complying with local wiring codes.
• To limit a voltage drop, and insure efficient operation, use No.12 AWG (14 mm
2
) wire or larger as required by
local electrical codes.
• Always connect to a branch circuit with circuit breaker or fuse protection with an electrical rating greater than the
model hand dryer’s rated amperage shown in Table 1 - Electrical Specifications.
• To avoid a hazard due to inadvertent resetting of the thermal cutout, the hand dryer must not be supplied through an
external switching device, such as a timer, or connected to a circuit that is regularly switched on and off by the utility.
• Each automatic model hand dryer must have a dedicated circuit.
• Route all field wiring away from moving parts within the hand dryer.
CAUTION
Improper mounting could result in personal injury or property damage.
• Follow the mounting height recommendations in Table 2.
• On a stud wall, one side of the hand dryer should be mounted to an existing stud.
1. Remove all packing material. Recycling is recommended.
2. Carefully remove the hand dryer from the shipping carton, using care not to drop the appliance.
3. Inspect carefully for any damage that may have occurred during transit. Check for any loose, missing or damaged
parts. If the hand dryer is damaged, promptly inform the dealer where you purchased it.
Models
Type
Electrical Inputs
Rated Amperage
Rated Watts
Certifications
L48-XXX
Automatic
230 VAC, 50/60 Hz
4.1 A
950
This appliance is not intended for use by young children or persons with physical, sensory or mental disabilities
unless adequately supervised by a responsible person to ensure they can use the appliance safely. Young children
should be supervised to ensure they do not play with the appliance.