beautypg.com

Installation, Adjusting dryer controls, Table 2 table 3 – World Dryer SMARTdri Series K and K4 User Manual

Page 4: Table 4

background image

4

Installation

1. Disconnect the power source.

2. Using Table 2 to determine the recommended mounting height, select a mounting location for the hand dryer where

no reflective surfaces or objects (such as a hand basin) are directly under the infra-red sensor eye. The infra-red

sensor eye is visible from the bottom of the dryer and is located just inside the dryer’s nozzle area. The minimum

mounting distance from bottom of the dryer to a reflective surface is 18 in (46 cm). When two or more dryers are

installed, they should be spaced apart 24 in (61 cm)

3. Use the security hex key supplied to turn the cover mounting screws

clockwise to remove the cover from the dryer.

4. Place the hand dryer base on the wall at selected location and using the base as a template, mark locations for the 4

mounting bolt holes on the wall.

5. Fasten the base to the wall, using the type of bolts recommended in Table 3

6. Each dryer must have is own dedicated circuit.

7. Connect the dryer to the nearest suitable distribution panel.

8. Replace cover, turn screws

counter-clockwise making certain not to over-tighten.

IMPORTANT:

Consult local and general regulations before performing dryer installation. Ensure the electrical

network is not overloaded. Always connect to a dedicated branch circuit with circuit breaker or fuse protection and

an electrical rating greater than the model hand dryer’s rated amperage shown in Table 1 - Electrical Specifications in

accordance with the NEC (National Electrical Code) and/or CEC (Canadian Electrical Code).

K-XXX Series Models

Motor Setting

Power Usage (Watts)

Heater "OFF"

Heater “ON”*

Hi

800

1200

Med

575

975

Low

400

800

Recommended Mounting Heights from Floor to Dryer Bottom Edge

in. (cm.)

Men’s washrooms

46 (117)

Women’s washrooms

44 (112)

Children’s washrooms, ages 4-7

32 (81)

Children’s washrooms, ages 7-10

36 (91)

Children’s washrooms, ages 10-13

40 (102)

Children’s washrooms, ages 13-17

44 (112)

Handicap Mounting Height

37 (94)

Table 2

Table 3

Type of Wall

Type of Bolt

Minimum Bolt Length

Hollow Tile, Lath, Wall Board or Metal

1/4” (M6) screw Type or Wing Type

toggle Bolts

Dependent on wall

thickness

Cement, Brick, or Tile Covered Cement or Brick

1/4” (M6) Stud Type Expansion Bolts

3” (76mm)

Stud Wall with wood Backing

No 16 (M8) Wood Screws

23/4” (70mm)

Table 4

The hand dryer has adjustable controls for (3) levels of operation – Hi, Med and Low. The dryer can be operated with

the heating element “ON” or “OFF”. The dryer’s power usage for the range of operation is shown in Table 4.

Note: The factory setting for the dryer controls is motor “Hi” and heater “ON”.

Adjusting Dryer Controls

K4-XXX Series Models

Motor Setting

Power Usage (Watts)

Heater "OFF"

Heater “ON”*

Hi

850

1250

Med

600

1000

Low

425

825