American Dryer Corp. ML-175DR User Manual
Page 34
30
American Dryer Corp.
113406-1
IMPORTANT: There is no regulator provided in a liquid propane (L.P.) dryer. The water column
(W.C.) pressure must be regulated at the source (L.P. tank) or an external regulator
must be added to each dryer.
b. Steam Models
Check to ensure that the steam damper is functioning properly.
The steam damper should not “slam” (open or closed) when it reaches the end of (piston) travel.
Additionally, the steam damper should not bind and/or stop during travel. If either of these conditions
occur, the flow control must be adjusted. Refer to the bottom illustration on page 27 for air adjustment
instructions.
6. Make a complete operational check of ALL safety-related circuits (i.e., lint drawer switch and sail switch
on gas models).
NOTE: To check for proper sail switch operation, open the main door and while holding main door
switch plunger in, start the dryer. The dryer should start but the heat circuit should not be
activated (on). If the heat (burner) does activate, shut the dryer off and make the necessary
adjustments.
7. Reversing basket (tumbler) dryers must never be operated with less than a 112 lb (51 kg) load (dry
weight), since the load’s weight affects basket (tumbler) coast time during a direction reversal command.
It is important that the basket (tumbler) come to a complete stop prior to starting in opposite direction.
Microprocessor Controller (Computer) Dryer Models
a. Spin and dwell (stop) times are not adjustable in the Automatic Mode and have been preprogrammed
into the microprocessor controller (computer) for 150-seconds spin time in the forward direction and
120-seconds in the reverse direction with a 5-second dwell (stop) time.
b. Spin and dwell (stop) times are adjustable in the Manual (Timed) Mode.
BASKET (TUMBLER) COATING
The basket (tumbler) is treated with a protective coating. We suggest dampening old garments or cloth material
with a solution of water and nonflammable mild detergent and tumbling them in the basket (tumbler) to remove
this coating.
8. Each dryer should be operated through one (1) complete cycle to ensure that no further adjustments are
necessary and that ALL components are functioning properly.
9. Make a complete operational check of ALL operating controls.
Microprocessor Controller (Computer) Programs/Selections:
Each microprocessor controller (computer) has been preprogrammed by the factory with the most commonly
used parameter (program) selections. If computer changes are required, refer to the computer programming
manual, which was shipped with the dryer.