beautypg.com

Compressed air supply air pressure – American Dryer Corp. Gas DSI/HSI/Electric/Steam/Phase 7 with S.A.F.E. D-40 User Manual

Page 34

background image

30

4. Steam Damper Air System Connections

This dryer is manufactured with a pneumatic (piston) damper system, which requires an external supply of
compressed air. The air connection is made to the steam damper solenoid valve, which is located at the
rear inner top area of the dryer just in front of the electric service relay box.

a. Air Requirements

There is no air requirement for dryers with the Electromechanical Steam Damper Option.

b. Air Connection

Air connection to system --- 1/8” N.P.T.

c. Air Regulation

No air regulator or filtration is provided with the dryer. External regulation/filtration of 80 PSI (5.51
bars) must be provided. It is suggested that a regulator/filter gauge arrangement be added to the
compressed air line just before the dryer connection. This is necessary to insure that correct and clean
air pressure is achieved.

COMPRESSED

AIR SUPPLY

AIR PRESSURE

Normal

80 PSI

5.51 bars

Minimum Supply

70 PSI

4.82 bars

Maximum Supply

90 PSI

6.21 bars

Shaded areas are stated in metric equivalents