3402231500/AC
The Environment sensor is a Network Management Teleservice
Card option.
The sensor remotely monitors the UPS environment by regularly
measuring the temperature and humidity, and checking the states of
two external contacts. It can also send alarms (e-mail, SNMP trap)
tripped by pre-set thresholds.
Connection is made via the Service port (Settings/Sensor) on the
Network Management Teleservice Card. The sensor is detected
automatically. Configuration and supervision use a menu that may be
accessed directly from the home page. For more information, see the
user manual of the Network Teleservice Management Card.
SENSOR CONNECTION (option)
66102
Settings/Sensor
ETHERNET
100M 10
M
UPS dat
a RS2
32
On = Link
Blink =
Act
UPS dat
a RS2
32
Settings/Sensor
ETHERNET
PHONE
Settings/Sensor
ETHERNET
100M
10M
Settings/Sensor
UPS
TECHNICAL CHARACTERISTICS
Physical characteristics
Dimensions (W x D x H)
132 x 66 x 42 mm
Weight
85 g
RoHS 100%
compatible
Storage
Storage temperature
range
-10°C to 70°C
Ambient conditions
Operating temperature
range
0°C to 40°C
Relative humidity
90% RH max. without condensation
Card performance
Supply voltage
5V
±5%
Supply current (all LEDs
ON and Environment
Sensor connected)
500 mA max.
Functions
Web supervision
5 browsers max. (http),
3 browsers max. (https)
Languages
English
Alarms
E-mail, SNMP TRAP, Web page
Log
400 measurements or events
Server protection
Up to 35 servers protected
Network
Fast ETHERNET, 10/100 Mbits, auto-negotiation
HTTP 1.1, SNMP V1, NTP, TFTP, SMTP,
BOOTP/DHCP
Identification
User name and password
Security
SSL 3.0, TLS 1.0
Browsers
Microsoft Internet Explorer 6.x or higher
NMS
Enterprise Power Manager (EPM)
Management-Pac 2
MIB
MIB II standard - MGE V1.7 MIB
Settings (default values)
IP network
BOOTP/DHCP enabled
IP address: 172.17.16.16
Subnet mask: 255.255.0.0
Gateway: 0.0.0.0
NTP server: pool.ntp.org
Web-page access control
User name: MGEUPS
Password: MGEUPS
Service-port menu access
control
Password: MGEUPS or mgeups
(not modifiable)
Date and time
Synchronise with an NTP server (GMT)
Service port
38400 bits/s, 8 bits, 1 bit stop, no parity
Standards
ITE (Information
Technology Equipment)
safety
IEC/EN 60950-1 (2005)
R&TTE
99/05/EEC
EMC
EN 61000-6-2 (2005), EN 61000-6-3 (2006)
2004/108/EEC
Low voltage
2006/95/EEC
FCC (Federal
Communication
Commission )
This equipment has been tested and found to
comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC rules. These limits
are designed to provide reasonable protection
against harmful interference when the equipment
is operated in a commercial environment.