beautypg.com

Introduction, Unpacking and checks, Overview – APC 66124 User Manual

Page 2: Indications, Switches setting

background image

3402231500/AC

The Network Management Teleservice Card (66124) is

recommended for central UPSs protecting entire networks or for UPS

units backing up critical loads.
With the card installed, the UPS has its own IP address and uses the

local computer capabilities to:
◗ supply web pages (http or https (SSL)) with information on status
conditions and measurements/settings/alarms,
◗ integrate an SNMP-based NMS such as HP OpenView, IBM Tivoli
Netview and Computer Associates Unicenter,
◗ communicate with shutdown modules installed on the protected
servers (Network Shutdown Module),
◗ send e-mail and SMS messages,
◗ control the ON/OFF function of the UPS and the outlets,
◗ monitor the Environment Sensor,
◗ Access the Teleservice solution for remote monitoring and
maintenance services of your UPS.

◗ One Network Management Teleservice Card (66124),
◗ One serial cable for configuration (3402226700),
◗ One phone cable for teleservice (3402226800),
◗ One installation manual (34022315EN),
◗ One Teleservice information form (3402228500),

PHONE port

ETHERNET port

Service port (Sensor/RS485)

Default settings, sensor configuration :

INTRODUCTION

The Network Management Teleservice Card must be
installed and used in accordance with manufacturer

instructions.

UNPACKING AND CHECKS

Installation manual

Network

Management

Teleservice Card

(66124)

66108

Settings/Sensor

ETHERNET

UPS dat

a RS232

100M

10M

Settings/Sensor

Settings/Sensor

Settings/Sensor

Settings/Sensor

66124

Settings/Sen

sor

ETHERNE

T

UPS data R

S232

100M 1

0M

Settings/Sen

sor

Settings/Sen

sor

Settings/Sen

sor

Settings/Sen

sor

OVERVIEW

INDICATIONS

LED

Colour

Status

Description

UPS Data

Green

OFF

ON

Flashing

Card not connected to phone

network

Card connected to phone

network, but no activity

Port is sending/receiving

CD

Orange

OFF

ON

Flashing

Modem is not connected

Modem is connected

Modem is connecting

LED

Colour

Status

Description

ACT

Green

OFF

ON

Flashing

Card not connected to network

Card connected to network, but

no activity

Port is sending/receiving

100M

Orange

OFF

ON

Port operating at 10 Mbits/s

Port operating at 100 Mbits/s

LED

Colour

Status

Description

Sensor

Green

OFF

ON

Flashing

Card starting

Card ready

Communication with environment

Sensor is operational

RS485

Orange

OFF

Flashing

Flashing

every seconds

Settings mode activated

Port is sending/receiving

Communication fault or

configuration errors

SWITCHES SETTING


MAC adress

PHONE port:

Green LED : Phone communication
with the UPS

Orange LED : Modem connection

ETHERNET port:

Green LED : Connection + activity

Orange LED : 10/100 M

Service port (Sensor/RS485):

Green LED : Communication with
the UPS

Orange LED :RS232 activity

Catalogue number

66124

SENSOR/RS 485

ETHERNET

( Settings)

100M

UPS Dat

a CD

PHONE

RESET

ACT

000623001C07

000623001C07

SA2

1

8

3

SA1

1

8

3

OFF

ON

OFF

ON