Setting the fan, Note, Intensive setting – Bosch DWK09M850 User Manual
Page 14: Fan run-on time, Lighting, Audible signal, Saturation display, Cleaning and maintenance, Risk of burns, Risk of electric shock
14
Setting the fan
Note: Always adjust the fan strength to meet current conditions.
If there is a large build-up of steam or fumes, select a high fan
setting.
Switching on
■
Press the
%
button.
The fan starts at setting 2.
■
Press the + or - button to change the fan strength.
Switching off
Press the
%
button.
Intensive setting
You can use the intensive setting if there is a large build-up of
odours and fumes/vapours.
Press the + button while the appliance is at ventilation setting
„
.
The intensive setting
›
is activated.
After 10 minutes, the electronics automatically turn the
appliance down to ventilation setting
ƒ
. If you wish to end the
intensive setting before the preset time expires, press the -
button until the required setting is reached.
Fan run-on time
Press the
r
button.
The display shows "9 min
r
".
Once this time has elapsed, ventilation switches off
automatically. If the lighting is switched on, it remains on.
Setting the run-on time
During the fan run-on time, press the + or - buttons.
You can set a run-on time of between 1 and 9 minutes.
Lighting
The lighting can be switched on and off independently of the
ventilation.
Press the
@
button.
With the spatter guard closed
You can switch on the lighting even when the spatter guard is
closed.
Press the
@
button on the bottom right of the appliance.
Setting the brightness
Press and hold the
@
button until the desired brightness is
reached.
Audible signal
Switching off the audible signal
With the ventilation and lighting switched off, press the
%
and +
buttons at the same time and hold them for approx. three
seconds.
An acknowledgement signal sounds.
Switching on the audible signal
Repeat the "Switching off the audible signal" process.
Saturation display
When the metal mesh grease filters or activated carbon filter
are saturated, the corresponding symbol flashes:
■
Metal mesh grease filter:
#
■
Activated carbon filter:
’
When this happens, do not delay cleaning the metal mesh
grease filters or replacing the activated carbon filter any further.
For instructions on how to clean the metal mesh grease filters,
please refer to the section Cleaning and maintenance.
While the saturation displays are flashing, they can be reset. To
do this, press the
#
button.
Switching over the display for circulating-air mode
For circulating-air mode, the electronic control display must be
switched over accordingly:
■
The extractor hood must be connected and switched off.
■
Press and hold the
%
and
r
buttons at the same time until
the
’
display lights up.
■
Repeatedly press the button combination to switch the
electronic control display back to exhaust air mode (
#
display).
Cleaning and maintenance
:
Risk of burns!
The appliance becomes hot during operation. Allow the
appliance to cool down before cleaning.
:
Risk of electric shock!
Penetrating moisture may result in an electric shock. Clean the
appliance using a damp cloth only. Before cleaning, pull out the
mains plug or switch off the circuit breaker in the fuse box.
:
Risk of electric shock!
Penetrating moisture may cause an electric shock. Do not use
any high-pressure cleaners or steam cleaners.
:
Risk of injury!
Components inside the appliance may have sharp edges. Wear
protective gloves.
Cleaning agents
Observe the information in the table to ensure that the different
surfaces are not damaged by using the wrong type of cleaning
agent. Do not use
■
harsh or abrasive cleaning agents,
■
cleaning agents with a high concentration of alcohol,
■
hard scouring pads or sponges,
■
high-pressure cleaners or steam cleaners.
Wash new sponge cloths thoroughly before use.
Follow all instructions and warnings included with the cleaning
agents.
Area
Cleaning agents
Stainless steel
Hot soapy water:
Clean with a dish cloth and dry with a
soft cloth.
Clean stainless steel surfaces in the
direction of the grain only.
Special stainless steel cleaning prod-
ucts are available from our after-sales
service or from specialist retailers.
Apply a very thin layer of the cleaning
product with a soft cloth.