Material safety data sheet, Physical and chemical properties, Stability and reactivity – PASCO CI-6620 EKG Sensor Electrode Patches User Manual
Page 3: Toxicological information
MATERIAL SAFETY DATA SHEET
Tab Diagnostic EKG Electrodes –
Conductive Silver
Revision Date: February 1, 2005
Page 3 of 6
Body Protection
Normal work wear.
9.
PHYSICAL AND CHEMICAL PROPERTIES
Physical State
Solid article
Color
Various
Odor
Odorless
pH
Approximately 3 - 5 (based on conductive salt contained within)
Specific Gravity
Not applicable
Boiling Range/Point (°C/F)
Not applicable
Melting Point (°C/F)
Not applicable
Flash Point (PMCC) (°C)
Not applicable
Vapor Pressure
Negligible
Solubility in Water
Completely insoluble
Vapor Density (Air = 1)
Not applicable
Evaporation Rate
Not applicable
VOC (g/l)
0.0
10. STABILITY AND REACTIVITY
Stability
Stable under normal conditions.
Conditions to Avoid
- Contact with incompatible materials
Materials to Avoid
- Strong oxidizing agents - Strong Bases
Hazardous Polymerization
Will not occur.
Hazardous Decomposition Products
- oxides of carbon – oxides of silver – oxides of tin - hydrogen chloride
11. TOXICOLOGICAL INFORMATION
Acute Toxicity
(Electrode) Primary skin irritation (modified Draize testing) was non-irritating.
(Electrode) This article has tested negative for skin sensitization by Buehler Patch testing.
(Electrode) USP Agar Diffusion testing has shown this article to be non-cytotoxic.
Chronic Toxicity/Carcinogenicity
This product is not expected to cause long term adverse health effects.
Genotoxicity
This product is not expected to cause any mutagenic effects.
Reproductive/Developmental Toxicity
This product is not expected to cause reproductive or developmental health effects.