4 output adjustment, 5 total pump output – Nova-Tech LMI Series AA-B-C-E-J-P Metering Pumps User Manual
Page 26
26
6.4
Output Adjustment
Once the pump has been primed, an appropriate output adjust-
ment MUST be made. Pump output should be calculated and
adjustments made accordingly.
6.5
Total Pump Output
Calculate the total output of the pump as follows:
PUMP OUTPUT = MAX PUMP OUTPUT
x % SPEED x % STROKE
Example: P151-392SI
Use MAX Output (from dataplate on bottom center of pump
control panel) = 24 GPD (24 gallons per day).
If the pump is set at 60% speed and 70% stroke length, the ap-
proximate pump output is:
24.0 x 0.60 x 0.70 = 10.08 GPD (gallons per day). Divide by 24
(hours in one day) to calculate in gallons per hour.
Ifpumpisnotequippedwithspeedadjustment,calculatebyMax
Pump Output x % Strokeonly.