TURNING ON THE DEVICE

GROUND BALANCE

To turn on the device, rotate the On/Off knob to ON. Turn the same knob to OFF position

when you want to turn off the device. When the device is turned on, a melody will be heard

and approximately 10 seconds later you will hear a long beep indicating that the device is

ready to use.

The device will provide more depth at on position. However, to better discriminate ferrous

metals, using the device in mineral modes and the iron discrimination at maximum position

is recommended.

Especially in mineralized ground target signal is negatively affected by the ''noise'' caused by

ground mineralization. This situation may prevent the detector from getting a clean signal

from the target necessary for metal detection and accurate discrimination. Ground balancing

is a process through which the metal detector is able to cancel out the negative effects

caused by ground mineralization.

To ground balance, holding the search coil 5cm. above the ground, sweep it right and left,

keeping it parallel to the ground and slowly turn the ground balance knob clockwise until the

noise is gone and the device is silent. If you cannot ground balance the detector, gradually

decrease the sensitivity and repeat the above steps.