Throttle body injection (tbi) cleaning procedure – MotorVac CarbonClean System II LE-1 User Manual
Page 22

Overview
1998 MotorVac Technologies,
xxi
Throttle Body Injection (TBI) Cleaning Procedure
Follow these steps to circulate the cleaning mixture through the
TBI
unit to clean the throttle body,
injector screens, and pressure regulator.
1.
Verify
that
TBI Setup
Steps 1-11
above have been completed before continuing.
2.
Refer to the vehicle's service manual for the manufacturer's recommended PSI.
3.
Adjust Time for 10 minutes.
4.
Press and hold the Start/Run switch.
5. Turn
the
Pressure Adjust
regulator clockwise until closed. This will clean the TBI unit and
filter the particles through the LE-1’s filtering system.
6.
Release
the
Start/Run switch. Check all connections for leaks.
•
Make a note of the fuel pressure reading; this is the true opening pressure of the vehicle’s
pressure regulator without vacuum assist when the engine is at normal operating
temperature.
•
NOTE: By turning the Pressure Adjust regulator in and out and “PULSING” the
mixture from time to time, the cleaning process will be enhanced in this mode.
7.
After the 10 minutes has expired adjust
Timer
knob for an additional 30 minutes. (Run time may
be adjusted depending on the condition of the vehicle’s fuel system.)
8.
Press
the
Start/Run
switch.
9.
Start the vehicle
to begin the fuel system cleaning process.
10.
When the run time expires, the cleaning is complete. The unit will automatically shut off and the
LE-1’s alarm will sound.
11.
Turn OFF the vehicle's ignition.
12.
Turn
the
Pressure Adjust
regulator counterclockwise on the unit to open it and release residual
pressure.