RE- ASSEMBLY OF THE PUMPSET.


THE PUMP CAN BE RE- ASSEMBLED BY REVERSING THE ABOVE PROCEDURE. PLEASE HOWEVER
NOTE THE FOLLOWING:

ALWAYS REPLACE ELASTOMER ELEMENTS.
REPLACE LOCKING SPACER IF REQUIRED DURING RE-ASSEMBLY.


OIL SPECIFICATIONS


A) EXXON UNIVOLT 61
B) SHELL TELLUS 29.
C) CHEVRON SUPERLA 10 FDA APPROVED

USE NON-CONDUCTING, NON-FOAMING, NON-DETERGENT FDA APPROVED OIL ONLY



PLEASE NOTE THE SEAL CHAMBER CONTAINS APPROX. 0.7 LITRES OF OIL
.

RECOMMENDED SPARES FOR TWO YEARS OPERATION:

SR. NO. PART

NO. DESCRIPTION QTY.

1 535-031-00

MECHANICAL

SEAL

2

2

535-024-66

“O” RING SET

1

3 260-034-66

CABLE

GROMMET

1

4

260-016-66

CABLE LEAD GROMMET

1

5 020-002-07

UPPER

BEARING

1

6 020-021-07

LOWER

BEARING

1

7a 300-116-01 IMPELLER

(60Hz)

1

7b 300-114-01 IMPELLER

(50Hz)

1

8

720-015-80

WEAR RING

1