Hrc fuse recommended – Mody Pumps MS 482 User Manual
Page 6
HRC FUSE RECOMMENDED
MAINS VOLTAGE AT SITE
MS 480 MS 481 MS 482
220 VOLTS 3 PHASE
35 AMPS
40 AMPS
40 AMPS
380 VOLTS 3 PHASE
20 AMPS
25 AMPS
25 AMPS
415 VOLTS 3 PHASE
20 AMPS
25 AMPS
25 AMPS
460 VOLTS 3 PHASE
20 AMPS
25 AMPS
25 AMPS
575 VOLTS 3 PHASE
15 AMPS
20 AMPS
20 AMPS
TROUBLE GUIDE CAUSE REMEDY
1.FUSES BLOWN. 1.REPLACE FUSES
2.CABLE DAMAGED 2.SHORTEN/REPLACE CABLE
PUMP DOES NOT START
3.NO POWER. 3.CHECK POWER SUPPLY
4.BLOCKED IMPELLER. 4.CLEAN BOTTOM PARTS.
5.STATOR WINDING BURNT. 5.REPLACE STATOR.
1.BLOCKED IMPELLER. 1.CLEAN BOTTOM PARTS.
2.IMPELLER ROT.WRONG 2.SHIFT TWO PHASE CONN.
PUMP STARTS BUT STOPS
. 3.CONNECTED FOR WRONG 3.CHECK & RECONNECT.
VOLTAGE.
4.VOLTAGE TOO LOW/HIGH. 4.APPROACH POWER CO.
5.LIQUID DENSITY HIGH 5.HIGHER HP REQUIRED.
6.BI-METAL TRIPS. 6.CHECK CURRENT.
1.IMPELLER ROT.BACKWARD. 1.SHIFT TWO PHASE CONN.
2.PUMP WORN DOWN. 2.REPLACE IMPELLER.
PUMP GIVES TOO LITTLE
3.LONG HOSE AND DIAMETER 3.CHECK PRESSURE LOSSES
WATER.
TOO SMALL.
4.PRESSURE HEAD TOO HIGH 4.INSTALL BIGGER PUMP.
5.WEARING RING WORN OUT. 5.REPLACE WEAR RING.