3 ~ Direct on –line starting DOL

Motor connection:

Ʀ

1 Power Supply Cable

+ 1 Control Cable

Color Coding

U

Black

Power Supply

V

Brawn

W

Grey

PE

Yellow

F1

Black

Control F2

Brawn

D*

Grey

1 Power Supply and

Control Cable

Color Coding

U

Black-1

V

Black-2

W

Black-3

PE

Yellow

F1

Black-4

F2

Black-5

D*

Black-6

*Not available for PX1-65.0 Series

Internal Connection on Motor’s Terminal Board

U1, U2 :

Black

V1, V2 :

Red

W1, W2 :

Orange

F1 F2 D

U V W

Th

ermal s

witches

Mo

is

tu

re

PE

3~ Direct - on - line

starting DOL

Motor connection : ǻ