TROUBLE GUIDE CAUSE REMEDY

1.FUSES BLOWN. 1.REPLACE FUSES

2.CABLE DAMAGED

2.SHORTEN/REPLACE CABLE

PUMP DOES NOT START

3.NO POWER

3.CHECK POWER SUPPLY

4.BLOCKED IMPELLER

4.CLEAN WET END

5.STATOR WINDING BURNT. 5.REPLACE STATOR.

6.CONTACTOR COIL BURNT 6.REPLACE COIL

7.SEAL PROBE SENSOR

7.CHANGE OIL/MECH. SEALS

1.BLOCKED IMPELLER. 1.CLEAN BOTTOM PARTS.

2.IMPELLER ROT.WRONG 2.SHIFT TWO PHASE CONN.

PUMP STARTS BUT

3.CONNECTED FOR WRONG 3.CHECK & RECONNECT.

BUT STOPS

VOLTAGE.

4.VOLTAGE TOO LOW/HIGH. 4.APPROACH POWER CO.

5.PUMP RUNNING DRY 5.SWITCH OFF POWER

6.WATER TOO WARM 6.SWITCH OFF POWER

(ABOVE 60 DEGREES C)

1.IMPELLER ROT.BACKWARD. 1.SHIFT TWO PHASE CONN.

2.PUMP WORN DOWN. 2.REPLACE IMPELLER.

PUMP OUTPUT LOW

3.LONG HOSE AND DIAMETER 3.CHECK PRESSURE LOSSES

TOO SMALL.

4.PRESSURE HEAD TOO HIGH 4.INSTALL BIGGER PUMP.

5.LEAKING/CRACKED OUTLET 5.REPLACE OUTLET/GASKET


MOTOR PROTECTION

IT IS ESSENTIAL THAT THE PUMP BE USED WITH A STARTER AND PREFERABLY A PANEL

BOARD. PANEL BOARDS INCORPORATING ALL PROTECTIVE DEVICES ARE AVAILABLE WITH US.

THE FULL LOAD AMPERE RATINGS OF THE THREE MODELS ARE AS PER TABLE BELOW. THE

OVERLOAD RELAY IN THE STARTER SHOULD CHOSEN ACCORDINGLY AND AMPERES SET AT THE

FULL LOAD SETTING FOR THE PARTICULAR MODEL OF THE PUMP.(DETAILS BELOW ARE FOR

460 VOLT PUMPS. CHECK FULL LOAD AMPERES FOR DIFFERENT VOLTAGES ON PUMP NAME

PLATE)


MODEL FULL LOAD AMPERES

.


230v

460v

NC 06360M

20 AMPS

9.8 AMPS

NC 08360M

24 AMPS

12 AMPS

NC 10360M

31 AMPS

15.5 AMPS