beautypg.com

Important precautions, Principle of operation, Instructions for use – Mityvac MVA6832 CLAMP-ON AUTO-REFILL KIT User Manual

Page 2

background image

Page Number - 2

Form 823530

Important Precautions

· Brake fluid is highly corrosive.

Wear gloves and approved safety

goggles at all times, and prevent

contact of the fluid with painted

surfaces.

· Consult and follow the vehicle

manufacturer’s recommended

procedures when servicing any

hydraulic system.

· Properly dispose of old fluids, and

replenish hydraulic systems with

new brake fluid from freshly opened

containers.

Principle of Operation

This unit is designed to automatically

maintain the level of new brake fluid

in the master or slave cylinder of a hy-

draulic brake or clutch system while the

system is bled manually or by vacuum.

Fluid flows from a reservoir into the

master cylinder by means of a tube and

base. The unit has a ¼ turn valve for

turning the flow on or off, and means for

adjusting the level of fluid in the master

cylinder. A 40 oz (1200 ml) reservoir is

included for use when dispensing fluids

from bulk containers. Two adapter caps

are also included, which allow direct ad-

aptation of standard 12 oz. and 32 oz.

brake fluid bottles to the valve assembly

and base.

Instructions for use

Important: This unit is designed for

servicing a variety of vehicles in a

safe, convenient manner. However,

the varying shapes, sizes, designs and

locations of master cylinders prevent its

use on every vehicle and application.

Check the unique design and location

of your master cylinder prior to proceed-

ing with the following instructions.

1. Fill the 40 oz (1200 ml) reservoir

with vehicle manufacturer’s recom-

mended brake fluid, to a level

exceeding the amount of fluid to be

bled (Fig 1), and install the lid. Or,

remove the lid from a standard new

12 oz. or 32 oz. bottle of brake fluid,

and thread on the appropriate size

Adapter Cap.

2. Clean the exterior of the master

cylinder and master cylinder cap

to prevent dirt from entering the

master cylinder when the cap is

removed.

3. Remove the cap from the master

cylinder, and set the Refill Base

onto the neck of the master cylinder.

4. Clamp the base to the neck of the

master cylinder by tightening the

Sliding Block Knob (Fig 2).

5. Install the Adjustment Spring onto

the neck of the Valve Assembly as

shown (Fig 3).

6. Slide the neck of the Valve As-

sembly through the hole in the

Refill Base, and use the Adjustment

Spring to align the bottom of the

neck with the MAX fill line on the

master cylinder (Fig 3).

7. Remove the Valve Assembly from

the base and insert it into the lid

of the pre-filled Reservoir Bottle or

into the Adapter Cap installed on a

bottle of brake fluid (Fig 4).

8. CHECK TO ENSURE THAT THE

VALVE IS IN THE “CLOSED” POSI-

TION.

9. Turn over the reservoir/bottle and

valve assembly, and insert it back

into the Refill Base (Fig 5).

10. Open the valve to allow fluid to flow

into the master cylinder. Leave

the valve open while bleeding the

hydraulic system, and the unit will

automatically maintain the level of

fluid at the MAX fill line.