Health physics division, Description, 3 sided lead shielding – Mirion Technologies SPIR-Ident Vehicle G User Manual
Page 2: Remote cameras control option, With or without occupancy signal functions, Gamma detection and identification capability

Health Physics
Division
Since norms, specifications and designs are subject to occasional change, please ask for confirmation of the information given in this publication.
Mirion Technologies (MGPI) Inc
5000 Highlands Parkway
Suite 150
Smyrna Georgia 30082
USA
T +1.770.432.2744
F +1.770.432.9179
Mirion Technologies (MGPI) SA
Lieu-Dit Calès,
Route d’Eyguières
F-13113 Lamanon
France
T +33 (0) 4 90 59 59 59
F +33 (0) 4 90 59 55 18
Mirion Technologies (RADOS) Oy
P.O. Box 506
FIN-20101 Turku
Finland
T +358 2 468 4600
F +358 2 468 4601
Mirion Technologies (RADOS) GmbH
Ruhrstrasse 49
DE-22761 Hamburg
Germany
T +49 (0) 40 851 93-0
F +49 (0)40 851 93 256
Mirion Technologies Shanghai Branch
Room 801, 78 Jiangchang
San Lu, Zhabei District
Shanghai 200436
China
T +86 21 6180 6920
F +86 21 6180 6924
SPIR-IDENT VEHICLE - G
Detection and Identification - Risks Prevention
www.mirion.com
144207EN-E
DESCRIPTION
●
1 to 4 detection pillars including each a 2 or 4 liter
NaI(Tl) gamma detector
●
3 sided lead shielding
●
Each gamma detector is associated with a fast digital
spectrometer
●
Standard or Panel PC with SPIR-IDENT Server software,
Portal and Expert mode interface
●
Includes SIA identification algorithm designed for
challenging Homeland Security issues
●
Remote cameras control option
●
With or without occupancy signal
FUNCTIONS
●
0.5 second continuous elementary spectra acquisition
and sourceless stabilization
●
Count rate and dose rate calculation, alert criteria
monitoring
●
Real-time identification per channel and group of
channels
●
Spectra accumulation during occupancy for preset time
with resume capability
●
Automated report per measurement including pictures
(user comments can be included)
●
Sliding spectra analysis between occupancies to
monitor background and for vehicle profile analysis
PERFORMANCES
●
Isotope list:
according to ANSI N42-38, IEC and IAEA standards
Industrial, SNM, Medical and NORM radionuclides
●
Gamma detection and identification capability:
○
according to configuration, designed to exceed ANSI
N42-38 (vehicle, static mode)
○
example: identifies 10 μCi 137Cs shielded with
3 cm (1.1 in) iron (ANSI requirement: 85 μCi)
○
includes special processing for shielded or masked
isotopes for example SNM masked by medicals or
NORMs
COMMUNICATION
●
Ethernet (network) connectivity
DIMENSIONS (PER PILLAR)
●
Body: 148 x 50,2 x 22,2 cm (57 x 19,73 x 8,74 in)
●
Base: Ø 32 cm (12.6 in)
●
Weight: 58 kg (128 lb)
Expert mode display
Portal interface detailed results
Vehicle Portal interface display