beautypg.com

Mechanical installation, Removal, Moisture protection – Max Machinery 290 Series Frequency (269, 294 and 295) User Manual

Page 6: Electrical installation, Wiring, Frequency single phase, Frequency quadrature

background image

6

IH 295-000-350 • rev. 6/2011 • ©2010-11 Max Machinery, Inc.

Model 295, 296

Mechanical Installation

1. The transmitter is attached to the flow meter’s threaded magnet shield. Hand tighten only. (~ 3 ft-lb)
2. The transmitter lid has four thread paths. To realign the cable, remove the lid and rotate up to 180°
and retighten using an alternate starting point. Tighten to compress the O-ring seal.

Removal

1. Remove electrical connections
2. Unscrew transmitter, using a wrench if necessary.

Removal note: The transmitter does not need to be removed from the flow meter for any field servicing or adjustments.
Normally, the flow meter and transmitter are shipped back to the factory for calibration or service as a unit. If the
transmitter needs to be removed from the flow meter for installation, be sure to retighten the transmitter snugly in order
to ensure proper sensor alignment.

Moisture Protection

On all models, the housing is designed as a liquid and vapor-tight enclosure. There are O—ring seals
at the lid and possibly also the base of the housing — these need to be fully seated. A properly sealed
transmitter will prevent the formation of damaging moisture inside the housing.
Turck connector Model: The connector is sealed to the lid at the factory and is ready for use.
NPT Model: To ensure a moisture-tight seal, apply appropriate sealant to the threads at installation.

Electrical Installation

Wiring

The electrical connector versions are pre-wired inside the transmitter and ready to accept a mating
cable (available from the factory). The liquid-tight, NPT models need to be wired during installation
as shown in the tables below:

an ISO 9001:2008 certified company

Installation - Model 295, 296

294 NPT model

295/296 NPT Model

Turck Connector

Mating Cable

Wire Color

Pin #

Case Ground

In-lid

Case

Blue

3

Common

1

Com

Black

4

Power 5-26 Vdc

2

V+

Brown

1

Pulse Output

3

Ph A

White

2

N/A

NC

Grey

5

Frequency

Single Phase

294 NPT model

295/296 NPT Model

Turck Connector

Mating Cable

Wire Color

Pin #

Case Ground

In-lid

Case

Blue

3

Common

1

Com

Black

4

Power 5-26 Vdc

2

V+

Brown

1

Output Phase A

3

Ph A

White

2

Output Phase B

4

Ph B

Grey

5

Frequency

Quadrature

2

1

4

5

3

2

1

4

5

3