Never try to repair or dismantle the air conditioner yourself. Incompetent repairs result in
loss of warranty and can endanger the user.

Problem

Cause

Solution

The unit does
not function

Check the plug fuse. Check
the mains outlet by connecting
another appliance

Connect to a functioning outlet and
switch on

Water container indicator is on

Empty water container

Room temperature outside
operating temperature range

The unit does
not seem to
perform

In direct sunlight

Close curtains

Windows or doors open, many
people or heat source in room
Dirty filter

Clean or replace filter

Air inlet or air outlet blocked

Remove blockage

Room temperature lower than
selected value

Change temperature selection

The unit is noisy

Unit stands uneven

Place on even surface (less vibrations)

The compressor
does not work

Overheat protection probably
activated

Wait until room temperature lowers

TROUBLE

SHOOTING

Model

AMC

7KM-410

AMC

10KM-410

AMC

12KM-410

Cooling capacity

measured conform EN 14511

BTU/h

6500

8300

9600

kW

1.9

2.4

2.8

Mains

220–240 V / 50 Hz / 1 phase

Power consumption

W

690

830

1030

Current

A

3.0

3.7

4.5

Dehumidification

L/24h

24

28.8

36

Air delivery

m

3

/h

300

350

350

Recommended room size

m

2

12

18

24

Refrigerant

type

R410A

Compressor

rotary

Fan speeds

2

Thermostat

°C

18 – 32

Timer

h

1 – 8

Dimensions (W x H x D)

mm

377 x 750 x 400

Weight

kg

29

30

32

Subject to modifications without prior notice. Please refer to the rating label for greater precision.

TECHNICAL

DATA

This manual is related to the following products: