13.

Select End Plate (Dead): End plate with threads in hub. When assembled, kidney ports in end
plates must be on intake side.

14.

Assemble End Plate (Dead): Position end plate over shaft, place on body, assemble screws, snug,
loosen one turn.

15.

Assemble Bearing: Place bearing on shaft, using bearing pusher, position bearing in end plate.

16.

Check Movement of End Plate: End plate must move back and forth. If no movement, top clear-
ance is not in center-reset top clearance. If moves, snug screws, remove from fixture, tighten screws.

17.

Adjust End Clearance: Rotor is snug against drive end plate. Using inner-race tapper, tap inner-
race of bearing (very lightly) in dead end plate until rotor is free. Push and turn, pull and turn, until no
drag on either end plate. For finer adjustment start air motor, adjust by sound.

18.

Assemble Seal: Press into end plate, small amount of grease on seal.

19.

Assemble End Cap: Into end plate.

20.

Test Air Motor: For normal duties.