Phoenix 1400 – Luna PHOENIX 1400 User Manual
Page 2

PHOENIX
TM
is a trademark of Luna Innovations Incorporated.
©Luna Innovations Incorporated, Roanoke, VA
All rights reserved.
PHOENIX 1400
LTPHO1400 REV. 005 04/01/2013
PARAMETER
MIN
TYP
MAX
UNITS
Wavelength
Mode Hop Free Tuning Range
1515
1565
nm
Wavelength Set Point Resolution
0.01
pm
Absolute Accuracy
1
±1.5
pm
Wavemeter Accuracy
2
±0.5
pm
Wavemeter Linearity
±50
fm
Stability
3
±50
pm
Tuning
Tuning Rate
1
100
nm/s
Deviation from Linearity
4
±1.5
±2
GHz
Power
Range
6
10
mW
Accuracy
±5
%
Flatness
5
±7
±10
%
Ripple
5
±2
%
Noise
Spectral line width
6,7
1.5
MHz
Side mode suppression ratio (nearest mode)
6
43
50
dB
Relative intensity noise
6
-152
-145
dB/Hz
Spontaneous Emission Ratio
6,8
-50
-43
dBc/nm
Inputs
Auxiliary Detectors (SM FC/APC)
Min detectable
Max detectable
Damage threshold
0.02
10
0.03
12
50
0.05
15
mW
Electrical Trigger (BNC)
“Low” voltage
“High” voltage
-0.5
+2.0
0
+3.3
+0.8
+3.8
V
Outputs
Optical Power
SM FC/APC
Electrical Sweep and Retrace Triggers (BNC)
+1 M
load
+50 M
load
+2.5
+1.7
V
All measurements assume warm-up time of 1.5 hrs.
1
Determined by internal NIST-traceable gas cell reference.
2
Measured after wavelength auto-calibration.
3
For 24 hr period within ± 5 C after laser calibration.
4
Over full wavelength range at 10 nm/s.
5
At 10 mW tuning at 10 nm/s over full wavelength range.
6
Measured with laser set to 1540 nm with10 mW output power.
7
Phase noise distribution full width at half maximum at center wavelength integrated over 1 ms. Measurements indicate that the intrinsic laser
linewidth (the limit at which the integration time goes to zero) is less than 100 kHz.
8
Measured with optical spectrum analyzer set at 1 nm resolution bandwidth.
CLASS 1 LASER PRODUCT