Technical specifications – Alcatel-Lucent 7549 MGW User Manual
Page 2

Technical specifications
Protocol support
Wireless networks
• TDM
• ATM
• IP
SGW
• M3UA/SIGTRAN
• MTP3 NB
• MTP3 BB
Network attachment compliance
• ITU-T G.703
• ITU-T G.707
• ITU-T G.813
• ITU-T G.823
• ITU-T G.825
• ITU-T G.957
Voice CODECs
• G.711
• G.729ab
• EFR
• GSM HR
• GSM FR
• GSM EFR
• GSM AMR HR
• GSM AMR FR
• AMR
• AMR2
• AMR2 WB
Physical specifications
Chassis dimensions
• Height: 62.2 cm (24.5 in.)
• Width: 45.2 cm (17.4 in.)
• Depth: 47.3 cm (18.6 in.)
Rack dimensions
• Height: 200 cm (78.7 in.)
• Width: 60 cm (23.6 in.)
• Depth: 80 cm (31.5 in.)
Power
• Input voltage -40V DC to -60V DC
• Input current 65 A, dual feeds
• Power consumption: 3000 W
Operating temperature
• 5°C to 40°C (41°F to 104°F)
Regulatory compliance
Electromagnetic
compatibility (EMC)
• EN 300 386: Telecommunica-
tion Network Equipment,
EMC requirements
• EC 61000-4: Testing and
measurement techniques
• IEC 61000-4-2: Electrostatic
discharge
• IEC 61000-4-3: Radiated, radio
frequency, electromagnetic field
• IEC 61000-4-4: Electrical fast
transient/burst
• IEC 61000-4-5: Surge immunity
• IEC 61000-4-6: Immunity to
conducted disturbances, induced
by radio-frequency fields
• Telcordia GR-1089-CORE Iss 4,
Sections 2, 3, 4, 5, 6, 10
Safety
• UL 60950-1, 1st ed.: Safety of
information technology equipment
• CSA 22.2 60950-1-03 1st. ed.:
Safety of information technology
equipment
• CB Scheme/IEC 60950-1 1st ed.:
Safety of information technology
equipment
Power and grounding
requirements
• Telcordia GR-1089-CORE, Section
9 Bonding and Grounding
Climatic and mechanical
• ETS 300 019-2-1: Environmental
conditions and environmental
tests for telecommunications
equipment – Part 21: Specifica-
tion of environmental tests:
storage
• ETS 300 019-2-2: Environmental
conditions and environmental
tests for telecommunications
equipment – Part 22: Specifica-
tion of environmental tests:
transportation
• ETS 300 019-2-3: Environmental
conditions and environmental
tests for telecommunications
equipment – Part 23: Specifica-
tion of environmental tests:
stationary use at weather-
protected locations
• Telcordia GR-63-CORE Iss 3,
Sections 2, 4.1.1, 4.1.2, 4.1.3,
4.1.6
Fire resistance
• Telcordia GR-63-CORE, Sections
4.2 and 5.2
Seismic
• ETS 300 019-2-3/A1
• Telcordia GR-63-CORE Iss 3,
Section 4.4.1
Acoustics
• ETS 300 753 Class 3.1 (1997):
Acoustic noise emitted by tele-
communications equipment
• Telcordia GR-63-CORE Iss 3,
Section 4.6
www.alcatel-lucent.com
Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo
are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners.
The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility
for inaccuracies contained herein. Copyright © 2008 Alcatel-Lucent. All rights reserved.
CAR9718081120 (12)